Gauge water valve

Gauge water valve

Home › Forums › Beginners questions › Gauge water valve

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #848132
    Thomas Clarke
    Participant
      @thomasclarke78224

      IMG_20260514_113824I am in the process of putting my boiler back on the loco having just had it tested at Western Steam. I thought I would give all the boiler fittings a good clean before reattaching them to the boiler. On checking the seal in the valve I was surprised to see that a rubber seal had not been used and instead some sort of fibre was used. Does this need to be replaced with a rubber seal or could I just use ptf tape. I also need to replace the gauge glass but this is 4.5mm and I can only find 4 or 5 mm glass. Replies would much be appreciated.

      Thomas

      #848137
      Thomas Clarke
      Participant
        @thomasclarke78224

        IMG_20260514_113824

        #848156
        duncan webster 1
        Participant
          @duncanwebster1

          Graphited string is the traditional material. It works so why change it

          #848161
          bernard towers
          Participant
            @bernardtowers37738

            yes stick with the string rubber at elevated temps is not good

            #848166
            Speedy Builder5
            Participant
              @speedybuilder5

              Graphited string as Duncan says, if string is too thick, split the strands apart and use them. Buy a chunk and keep as come in handy for next time.

              #848201
              Chris Gunn
              Participant
                @chrisgunn36534

                Your water gauge glass could have been 3/16″ o/d. You may find some if you search for that.

                You could try a piece of 5mm steel to see if it will fit in the tube nuts, and go from there.

                Chris Gunn

                #848208
                Nigel Graham 2
                Participant
                  @nigelgraham2

                  Synthetic rubber O-rings work in these fittings. They are of ‘Neoprene’ or ‘Viton’ but I’m not sure off-hand which is the better here.

                  Do not use PTFE tape on boiler fittings. It shreds and the slivers can make mischief in clack-valves, injectors and gauge-glasses.

                Viewing 7 posts - 1 through 7 (of 7 total)