    tom hardy
    Participant
      @tomhardy75463

      plans

      #299938
      tom hardy
      Participant
        @tomhardy75463

        i have started building a shand mason fire engine westbury plans i have the 6 sheets of drawings and the castings. on sheet 4 there is a syphon box which appears from the photos to fit on the rear of the steam box. i cannot work out what it does and where do the pipes from the bottom of this box go to . some photos on the net show the pipes going to the crank bearing the drawing only show 1/16 oil holes no pipes

        where can i buy the suction and discharge (fire hose) or what can i make them from

        regards tom hardy

        #300015
        ianj
        Participant
          @ians

          Hi Tom.

           

          You are corect the box contains oil and 3 pipes go from the bottom and go to the crank bearings, if I remember correctly I put string in the pipes to act as wicks.

          This how I made my suction/discharge hoses:

           

          I length of plastic tube ( car windscreen washer type)

          slide a rod of steel/brass down the bore.

          mounted on the lathe, one end in chuck other supported by a tailstock centre

          then set the lathe to say 8 tpi screw cutting

          then as if winding a spring wrap a thin wire along the length of the tube

          remove from the lathe cover with white heat shrink sleeving and heat using a hot air gun.

          The end result looks really good with the wire looking like the ribs of the hoses.

          Hope that makes sense?

          If not I will try again.

           

          Do you have a copy of the build article from Model Engineer mag?

          If not I have scans of them & could put them on disc for you.

           

          There are some photos's of mine in my album

           

          Ian

          Edited By ian j on 28/05/2017 19:16:03

          #300066
          tom hardy
          Participant
            @tomhardy75463

            thank you ian j

            i will try to make the suction hose this way does the discharge hose be the same as i think it lays flat

            i am chasing the articles in model engineer so if you have copies that would be great

            tom

            #300075
            ianj
            Participant
              @ians

              Tom.

              I have sent you a private message.

              Ian