Vic, my inverter has a 'ramp up/down' setting which determines how fast the spindle gets up to speed, and slows down. It's not braking as such, just the time taken to go from selected speed to zero. Yours would appear to be on page 5-3 of the manual, called decel time (1-10 and 1-12) The default appears to be 1 sec, so it may have been altered. Chapter 4.4 shows how to alter the parameters. Without the unit in front of me, I can't help you on changing the settings, but if you work through the guide 4.4 you should be able to get to Group 1 (Basic parameter), then item 10 (decel) and set the value to 10 (=1second)
There is a section on braking resistors, but you may find that decel solves your problem. If all else fails, you could try a factory reset to get accel and decel to be 1 sec
Rgds,
John