What solenoid to use?

What solenoid to use?

Home Forums General Questions What solenoid to use?

Viewing 18 posts - 1 through 18 (of 18 total)
  • Author
    Posts
  • #433010
    Falco
    Participant
      @falco

      I live in a windy area and have wondering how to close the house ventilation flaps firmly using a solenoid. eg cooker fans, toilet vents etc. Most would be 6" or 8" pipes out through the outside wall with a flap closing off the flow somewhere along the length of the pipe between appliance and outside.

      I want the flap to open when a fan is switched on and vice versa. My problem is how to find / choose a solenoid that will hold a flap open for periods of use and not get so hot as to be dangerous. These would be placed in hidden areas of the building so they must be fairly foolproof. The necessary throw would be 1" – 2".

      I have some ex-equipment solenoids but I'm not up to speed enough to know whats safe to use in this sort of situation and what is not.

      Any advice on how to proceed will be welcome.

      #26892
      Falco
      Participant
        @falco
        #433016
        Brian Sweeting 2
        Participant
          @briansweeting2

          Instead of a solenoid have a look at 'duct damper actuators'.

          These come in a range of prices, you can even get small ones for car vent ducts. They are designed to motor open or closed so only require power to change state.

          You can also get complete duct dampers with actuators attached.

          #433019
          Jeff Dayman
          Participant
            @jeffdayman43397

            A very good damper drive actuator is the Honeywell Versadrive. I worked on developing these about 30 yr ago.

            **LINK**

            If you can find one you will not be disappointed. Honeywell may still sell variants, but not sure if modern ones are the same design.

            #433037
            Clive Hartland
            Participant
              @clivehartland94829

              There are some gravity type flaps set at a slight angle that only open when there is internal pressure. Often fitted to cooker hoods, no leccie iused at all.

              #433039
              John Haine
              Participant
                @johnhaine32865

                DC motor drive is likely to be better and cheaper, small geared motor driving a screw. You can buy complete units on eBay, search for linear actuator.

                #433043
                Clive Foster
                Participant
                  @clivefoster55965

                  Generic car door lock actuators are pretty powerful and can be found quite cheaply in various designs and sizes. You need the 5 wire "central" one for stand alone jobs. About a fiver off E-Bay.

                  I've used them as a powerful solenoid substitute. Around a "long inch" travel I think.

                  Clive

                  #433059
                  Georgineer
                  Participant
                    @georgineer
                    Posted by Clive Hartland on 13/10/2019 09:37:36:

                    There are some gravity type flaps set at a slight angle that only open when there is internal pressure. Often fitted to cooker hoods, no leccie used at all.

                    There's one fitted to my cooker hood. On a gusty day like today it goes:

                    flap flap flap flapflap flap flap flap flap flapflapflap flap flap flap flap flap flapflap flap flap flap flap flapflapflap flap flap flap flap flap flapflap flap flap flap flap flap flapflapflapflap flap flap flap flap flapflap flap

                    (repeat ad nauseam)

                    George

                    Edit:  the system software took out all my extra  spaces – you'll have to imagine the random pauses between flaps.

                    G.

                     

                    Edited By Georgineer on 13/10/2019 12:32:54

                    #433060
                    Circlip
                    Participant
                      @circlip

                      Gravity flap with adjustable weight?

                      Regards Ian.

                      #433160
                      Falco
                      Participant
                        @falco

                        Thank you to all who replied. A few good leads there and I'm leaning towards linear activator or the car door lock actuator for simplicity. I'll do a read-up and search for sources.

                        John

                        #433162
                        Howard Lewis
                        Participant
                          @howardlewis46836

                          Our cooker ventilator, also rattles if the wind is in the right direction.

                          When we lived near the sea, many years ago, to prevent excess draught burning all the sold fuel overnight, I made up a flap with a weight on an arm, and used this to bleed air into the flue, and limit the draught. Worked a treat, pure guesswork, of course!

                          Howard

                          #433168
                          Neil Wyatt
                          Moderator
                            @neilwyatt
                            Posted by Falco on 12/10/2019 23:13:26:

                            I live in a windy area and have wondering how to close the house ventilation flaps firmly using a solenoid. eg cooker fans, toilet vents etc. Most would be 6" or 8" pipes out through the outside wall with a flap closing off the flow somewhere along the length of the pipe between appliance and outside.

                            I want the flap to open when a fan is switched on and vice versa. My problem is how to find / choose a solenoid that will hold a flap open for periods of use and not get so hot as to be dangerous. These would be placed in hidden areas of the building so they must be fairly foolproof. The necessary throw would be 1" – 2".

                            I have some ex-equipment solenoids but I'm not up to speed enough to know whats safe to use in this sort of situation and what is not.

                            Any advice on how to proceed will be welcome.

                            Our bathroom fan came with one built in. The solenoid is very small.

                            #433173
                            not done it yet
                            Participant
                              @notdoneityet

                              While some (most) ventilation can be positively avoided, do not cover any ventilation designed to provide a draught for fuel burning appliances. As you say you only want to close those with flaps, you may well be aware of the risk of carbon monoxide poisoning.

                              #433206
                              duncan webster 1
                              Participant
                                @duncanwebster1

                                You could try 2 solenoids with an over-centre mechanism, one solenoid opens it, but the spring or weight keeps it open so the solenoid can be switched off, other solenoid vice versa, but I agree the actuator sounds best

                                Edited By duncan webster on 13/10/2019 23:59:19

                                #433450
                                Falco
                                Participant
                                  @falco

                                  Neil; anything over a force 5 will overwhelm the normal bathroom Louvre fans and make them rattle. I need to provide for the occasional force 9!

                                  Duncan: Wiring one solenoid , maybe. Two of them, no chance! No electrical genius here. A simple actuator seems my best solution. Most seem to be DC.

                                  I have never had one in the hand so to speak. Am I right in thinking that when the power is cut off them that they stay put in that position until re-activated?

                                  John

                                  #433451
                                  John Haine
                                  Participant
                                    @johnhaine32865

                                    At least as far as the ones I pointed out, that's correct. Motor drives leadscrew through gears, leadscrew moves pushrod. Applying force to pushrod will not turn motor, too much friction. Think of leaving electric car window open and turning off ignition.

                                    #433452
                                    Simon Williams 3
                                    Participant
                                      @simonwilliams3

                                      Try googling "belimo actuator" for a wide range of damper actuators – essentially a motor driven crank that turns trough 90 degrees. Other variants are available but looking at ebay at the moment there seem to be quite a few on offer around the £25 to 30 sort of mark.

                                      HTH Simon

                                      #433577
                                      Falco
                                      Participant
                                        @falco

                                        John, Simon, thank you, lots of useful info.

                                      Viewing 18 posts - 1 through 18 (of 18 total)