Southworth valve setting

Advert

Southworth valve setting

Home Forums Help and Assistance! (Offered or Wanted) Southworth valve setting

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #788063
    John Lawson
    Participant
      @johnlawson61116

      Does anyone know of any instructions on setting the valve for a Southworth 3 inch vertical pump, just guessing at the moment.

      Advert
      #788089
      noel shelley
      Participant
        @noelshelley55608

        You mean a weir type feed water pump ? Noel.

        #788279
        John Lawson
        Participant
          @johnlawson61116

          Yes but specificaly this 3″ pumpP1030089

          #788286
          Martin Johnson 1
          Participant
            @martinjohnson1

            Firstly the southworth series have no resemblance to the Weir product.  End of pedant outbreak.

            It is easiest to start with the two stops set close to each other.  The pump should then work, but will not travel full stroke.  You can then progressively move each stop out a bit and try again.  You will reach a point where the then stalls at one end, so put that stop back in a bit.  The settings tend to depend a bit on stroke speed, working pressure and motive fluid, so fine tune under steam if that is the intention, but rough set on air for convenience.