Apologies for the long post, but details never hurt. Here goes…
For a while now my workshop (side garage) has been dark and under powered with one lonely light bulb and one mains spur from the house going to a double socket and quite a few multiplugs – I have never been too worried about overloading the spur as I am only ever running one machine at a time.
However I would like to install a Ring Main so that I have plenty of socket outlets available around the workshop and I wouldn't have to keep on dragging an extension round or swapping out various tools for the other. I would also like to install some descent florescent lighting.
Last year I got an electrician to come have a look and give a informal quote. Due to the consumer unit being on the opposite side of the house he wanted to rip up half the house's floorboards (a snowball's chance in hell if SWMBO has anything to do with it) and have to completely empty the garage to do the installation (understandable but something I am loathed to do nor have the resources for). He very much had a "my way or the highway" attitude; which all in all meant nothing has progressed.
My intention is to get a qualified electrician to run a circuit on the outside of the house, either from the consumer unit or the service cable to a small 4way fuse box inside the garage with a couple of 30A MCB with RCD protection. I would then install the ring main myself and yes I am aware that this work will need to be notified and certified – leading onto my questions:
– Conduit and socket outlet type – The existing are all protected in metal conduit (although only up to the beams where the flex is secured to the wood) and have metal cases. Except the outside light switch which is plastic! Would it be sensible to follow suit with this or would plastic cases with clipped wall mounted T+E be acceptable?
I believe the regs say "All wiring systems and equipment have to be suitable for their intended location and use taking into account all extraneous influences" Although personally I struggle to see what one would be doing in the workshop to end up splitting a wire on the wall or smashing an outlet but there you go
– Lighting – Can I modify the existing lighting spur circuit to incorporate three florescent tube units? Do I need to be conscious of the power ratings and would it be advisable to use energy efficient lighting to keep the rating down? If not I will ask for a 6A MCB in the fuse box and wire the lighting from here.
If you've managed it this far then I owe you already and if you are able to constructively comment constructively then I would be indebted!
I'm sure there are many other points which I have forgotten but this is plenty for now.
Many thanks