vertial boiler water feed problems

vertial boiler water feed problems

Home Forums Beginners questions vertial boiler water feed problems

Viewing 9 posts - 1 through 9 (of 9 total)
  • Author
    Posts
  • #226955
    gavin compton
    Participant
      @gavincompton68796

      hi all

      bit of a werid problem (for me) i have a water tank plumbed to a little hand force water pump then to boiler with a check valve boiler fitting. i tryed steaming the boiler and found it almost impossable to raise pressure.i then noticed the water tank drained without me pumping it !!. so i blanked off the check valve and drained some water off and in 5mins or so i had the safety valve popping.

      so my question is should there be a shutoff valve in between boiler and pump ??? or am i doing something wrong ??

      thanks

      gavin

      #8020
      gavin compton
      Participant
        @gavincompton68796
        #226993
        Paul Lousick
        Participant
          @paullousick59116

          Boilers usually have a clack valve (check valve) between the boiler and the pump or injector and an isolation valve between the clack and the boiler so it can be isolated if it is leaking steam/water back to the tank.

          Is the tank higher than the boiler ? Water should not flow into the boiler unless the supply pressure is higher than the boiler pressure.

          Paul.

          #227018
          gavin compton
          Participant
            @gavincompton68796

            Hi,

            thanks for the reply.

            the top of the tank is level with the bottom of the boiler. i have a 90C clack valve on the boiler (new valve) with 5/32" pipe to a brand new hand pump (https://maccmodels.co.uk/live-steam-fittings/water-hand-pumps/3-8-ram-5-32-pipe-free-standing-hand-water-pump-front-pipe-fitti.html

            to tank via 5/32" pipe again. from pump out put to clack valve is about 3" rise.

            so yea im at a lost.

            thanks

            Gavin

            #227019
            Speedy Builder5
            Participant
              @speedybuilder5

              On SPEEDY (LBSC design), there is a 'clack' valve on the pump and another 'clack' valve on the boiler. It sounds as if steam is passing from the boiler through the boiler clack valve, condensing and sucking a small amount of water into the boiler. Steam will once again pass the boiler clack, condense and draw water. This continual process would eventually fill the boiler ? Do you hear the clack 'rattling' ?
              I would look at the boiler clack first and make sure it seals properly.

              BobH

              #227024
              gavin compton
              Participant
                @gavincompton68796

                HI thanks for the reply.

                the boiler does "prime" it self you can hear the water feed "sucking" when tank almost emety. i be removing the boiler clack valve today to be checking it and the pump too. think i might order some more pipe and a inline 1/4 turn valve as well.

                thanks

                Gavin

                #227104
                gavin compton
                Participant
                  @gavincompton68796

                  hi all

                  checked the clack valve it didnt rattle so opened it up dumped it in sonic cleaner put it back togeather now its rattling away. also pump wasnt rattling either so did the same ,so now i got 2 rattles ready to be reinstalled. would it be best to add a shut off inline while it all apart ??

                   

                  thanks

                  Gavin

                  Edited By gavin compton on 26/02/2016 17:04:17

                  #227562
                  gavin compton
                  Participant
                    @gavincompton68796

                    Hi all

                    Ok I tried again and boiler primed again.so I blocked water inlet with rubber tube.once boiler got 10-15psi I can remove the water plug and boiler won’t prime. Any ideas? I also noted the check valve does not have a spring in. I believed from some drawings I seen that there should be?.

                    Any advice?

                    Thanks
                    Gavin.

                    PS what a good safety valve? My simple spring and ball one works but fails on shut off lol

                    #227575
                    nigel jones 5
                    Participant
                      @nigeljones5

                      Clack doesn't or rather shouldn't need a spring. Ive never seen this happen, but fitting a light spring should fix things, if you can find one to fit which wont rust. The hand pump will probably be good for over 400psi so will easily overcome the spring resistance.