Mitsubishi vfd

Mitsubishi vfd

Home Forums Electronics in the Workshop Mitsubishi vfd

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #401368
    David Siddle 1
    Participant
      @davidsiddle1

      I'm needing a little help picking the correct drive. I've looked at the manual on line, but I'm still a bit confused Could anyone please tell me if the following model would be suitable for powering my 3ph fobco from domestic supply? Many thanks.

      FR-D720S-042SC-EC

      David

      #32009
      David Siddle 1
      Participant
        @davidsiddle1
        #401371
        Wingo
        Participant
          @wingo

          Hi,

          This is a 230v input single phase and 220v three phase ouput inverter. Rated at 0.75kw.

          Your motor will need to support 220 / or 230v phree phase supply, often by connecting in Delta on a dual rated motor.

          It will 'putting in a box' to protect it with room to be able to loose the heat generated.

          Then with correct configuration it will then work!

          If you not sure about the motor put up a photo of the motor rating plate.

          Michael

          #401377
          Brian Hutchings
          Participant
            @brianhutchings

            Hello David, You could try giving Direct Drives a call, I found them to be very helpful recently.

            Brian

            Direct drives

          Viewing 4 posts - 1 through 4 (of 4 total)