I’ve had my X3 from ArcEuroTrade in maybe 2007/8 but it’s that long ago I can’t be sure. It was around £700 It’s an early one for sure (the motor has a different brush end housing in black with protruding brush holders) and a complex sliding metal and plastic safety guard rather the later two part plastic one. The belt drive is I think the slightly later one with a conventional T5 profile.
I echo the safety guard issue mentioned above, the switch position can be tweaked to get it reliable. Cuts in one direction had the habit of opening the switch but it was with the guard closed. Holding the guard slightly open and it would never fail.
My motor lasted the period of any guarantee and maybe a week (dry conditions, 18 deg C round the clock and with very light use) The motor then failed without taking out the controller.
I got mine back into service with a dc motor from a Boxford TCL125/160. I made a new mounting plate, bored and broached a keyway into an off the shelf T5 pulley, using the original belt and connected it to the original controller.
The setting up procedure for the controller would be very useful but it appears to be unobtainium.
Three setting potentiometers, one possibly to compensate for the droop on load, the other for max current, another for max speed?
The motor is a permanent magnet one. Three wires to the controller are Positive, Negative and an Earth
PS most (all?) the connections to the controller are marked with ferrules that tie up with markings on the controller but they are all loose on the wires, the wire ends having no crimps, so the ferrules will fall off in a random heap unless you tie a knot in the wire or affix a suitable crimp as you remove each connection.
Edited By Martin 100 on 06/06/2020 14:41:53