      Hello,

      I have just manage to get myself a Fobco Star and am converting it back to 240V, however, I have been told that I can still use the original 6 spur switch for 240V but I am unsure which terminals to use, I have a couple of photos, on each side there is a bank of three terminals and they have been written on showing 1,2 and 3 and on the other side, A, B and C. Any advice welcome.

      I shall wire up an NVR switch on the wall next to the machine but really wish to keep it original.

      I am still looking for a suitable motor, the Crompton 3 phase unit looks almost like new so shall be selling this one on or exchange/swap.

      Below is a link the the switch photos.

      **LINK**

      #8844
      Madhatter
      Participant
        @madhatter
        #314142
        Brian Wood
        Participant
          @brianwood45127

          Madhatter,

          I suggest you try the old trick used on 3 phase contactors which uses all the ways.

          Couple mains Live to 1 and A to motor. Couple mains Neutral to 2 and B to a link wire which is then coupled to 3 and take C to the motor.

          If you have a test meter then check that through first, if not a batten lamp holder and wire to that as a load before transferring it all to the motor.

          Brian

          #314146
          Madhatter
          Participant
            @madhatter
            Posted by Brian Wood on 27/08/2017 10:33:01:

            Madhatter,

            I suggest you try the old trick used on 3 phase contactors which uses all the ways.

            Couple mains Live to 1 and A to motor. Couple mains Neutral to 2 and B to a link wire which is then coupled to 3 and take C to the motor.

            If you have a test meter then check that through first, if not a batten lamp holder and wire to that as a load before transferring it all to the motor.

            Brian

            Many Thanks Brian,

            I shall do this when I locate a single phase motor.

            Best

            Chris (Madhatter)

            #314150
            John Haine
            Participant
              @johnhaine32865

              If you are thinking of buying a single phase motor, why don't you but a VFD instead? Probably no more expensive (on eBay) and will result in a much more versatile and quieter machine.

              #314156
              Michael Briggs
              Participant
                @michaelbriggs82422

                +1 John, I made a nice Fobco Star out of two donor machines. It has a three phase motor and a VFD, runs very smoothly and rarely needs the belt moving on the pulleys.

                #314824
                Madhatter
                Participant
                  @madhatter

                  I had contemplated this but I did not really wish to buy armoured cable and all that goes with it, I found VFD's around £130 + shipping for a decent one (though may be looking in the wrong place) and then the additional cost and messing about when I can buy a new Crompton motor for the same, £130-delivered.

                  #314838
                  Ian P
                  Participant
                    @ianp
                    Posted by Madhatter on 01/09/2017 15:24:33:

                    I had contemplated this but I did not really wish to buy armoured cable and all that goes with it, I found VFD's around £130 + shipping for a decent one (though may be looking in the wrong place) and then the additional cost and messing about when I can buy a new Crompton motor for the same, £130-delivered.

                    Chris

                    New single phase motor or VFD? Its absolutely no contest!

                    Seriously do go the VFD route, you will not regret it. Even if it cost a bit more (which if it was my machine it would cost less) it is worth the premium.

                    As Michael said above. Its 10 years since I fitted a VFD to my Fobco and have never moved the belt since! That is spite of the fact that I use the machine for tapping M2 threads as well as drilling up to 16mm in steel (reduced shank drill) and also have deep counterbored holes 50mm diameter (with a sort of spigotted flycutter).

                    I mounted my VFD to one side of the motor so have no need of screened or armoured cable.

                    Ian P

                    #315750
                    Madhatter
                    Participant
                      @madhatter
                      Posted by Brian Wood on 27/08/2017 10:33:01:

                      Madhatter,

                      I suggest you try the old trick used on 3 phase contactors which uses all the ways.

                      Couple mains Live to 1 and A to motor. Couple mains Neutral to 2 and B to a link wire which is then coupled to 3 and take C to the motor.

                      If you have a test meter then check that through first, if not a batten lamp holder and wire to that as a load before transferring it all to the motor.

                      Brian

                      I have decided to stay with my original plan and use a 240V motor which has arrived, I just wish to run through these connections again only where you say couple mains neutral to 2 and B, then link a wire over to 3, then take C to the motor, but I only have the three wires and two of those are earthed on the body.

                      #315751
                      Hillclimber
                      Participant
                        @hillclimber
                        Posted by Ian Phillips on 01/09/2017 16:21:08:

                        I mounted my VFD to one side of the motor so have no need of screened or armoured cable.

                        Ian P

                        Ian, any chance of a photo? I am about to do the same thing and would be interested to see how you manages the bracketry.

                        Cheers, Colin

                        #315759
                        Madhatter
                        Participant
                          @madhatter
                          Posted by Madhatter on 07/09/2017 18:01:10:

                          Posted by Brian Wood on 27/08/2017 10:33:01:

                          Madhatter,

                          I suggest you try the old trick used on 3 phase contactors which uses all the ways.

                          Couple mains Live to 1 and A to motor. Couple mains Neutral to 2 and B to a link wire which is then coupled to 3 and take C to the motor.

                          If you have a test meter then check that through first, if not a batten lamp holder and wire to that as a load before transferring it all to the motor.

                          Brian

                          I have decided to stay with my original plan and use a 240V motor which has arrived, I just wish to run through these connections again only where you say couple mains neutral to 2 and B, then link a wire over to 3, then take C to the motor, but I only have the three wires and two of those are earthed on the body.

                          It's ok, I got it…finally! Thanks Brian, it works a treat!

                          #315761
                          Madhatter
                          Participant
                            @madhatter

                            Now I shall rig it all up to an Nvc… photos of before and after coming very soon.

                          Viewing 12 posts - 1 through 12 (of 12 total)