Posted by Michael Briggs on 08/09/2016 21:18:09:
Andy, The only time you need to overrate a VFD is in an application where there is a high starting torque. Not a requirement in my workshop. Regards, Michael.
Hi Michael,
I agree that it's not always necessary, sometimes you can "get away with it". I usually use the leadscrew or gear train with lathe, and found that the extra strain on the motor, overheated it on heavy interference cuts.
To be fair, this incident wasn't with a fan cooled inverter, and could account for that. There is a 10% margin on the power anyway.
I would only try running 1 VFD off several motors if you're confident you can handle the wiring situation.
Michael W
Edited By Michael Walters on 09/09/2016 09:32:13